Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of HCl-free solid phase extraction combined with ICP-MS/MS for rapid assessment of difficult-to-measure radionuclides, 1; Selective measurement of $$^{93}$$Zr and $$^{93}$$Mo in concrete rubble

Do, V. K.; Furuse, Takahiro; Murakami, Erina; Aita, Rena; Ota, Yuki; Sato, Soichi

Journal of Radioanalytical and Nuclear Chemistry, 327(1), p.543 - 553, 2021/01

 Times Cited Count:5 Percentile:65.59(Chemistry, Analytical)

A new HCl-free chromatographic separation procedure has been developed for sequential separation of Zr and Mo from concrete matrices. Accordingly, $$^{93}$$Zr and $$^{93}$$Mo could be sensitively and selectively measured by ICP-MS/MS using ammonia reaction gas. The recoveries of greater than 90% for Zr and Mo from concretes could be achieved. The measurement condition was optimized for complete suppression of interferences from $$^{93}$$Nb and peak tailing from abundant isotopes of Zr and Mo in concrete matrices. The removal of interferences was verified by measurement of radio-contamination-free concretes used as a sample matrix blank. Method detection limits of 1.7 mBq g$$^{-1}$$ and 0.2 Bq g$$^{-1}$$ were achieved for $$^{93}$$Zr and $$^{93}$$Mo, respectively, in the concrete matrices. The interference removal factor for Nb (equivalent to the decontamination factor in radiochemical separation) was of the order of 10$$^{5}$$, and the abundance sensitivity was of the order of 10$$^{-8}$$, indicating that the developed method is reliable for verifying the presence of ultralow concentrations of $$^{93}$$Zr and $$^{93}$$Mo. The present method is suitable for the rapid assessment of $$^{93}$$Zr and $$^{93}$$Mo for radioactivity inventory of concrete rubble.

Journal Articles

Rapid separation of zirconium using microvolume anion-exchange cartridge for $$^{93}$$Zr determination with isotope dilution ICP-MS

Asai, Shiho; Hanzawa, Yukiko; Konda, Miki; Suzuki, Daisuke; Magara, Masaaki; Kimura, Takaumi; Ishihara, Ryo*; Saito, Kyoichi*; Yamada, Shinsuke*; Hirota, Hideyuki*

Talanta, 185, p.98 - 105, 2018/08

 Times Cited Count:8 Percentile:31.98(Chemistry, Analytical)

Estimating the risks associated with radiation from long-lived fission products (LLFP) in radioactive waste is essential to ensure the long-term safety of potential disposal sites. In this study, the amount of $$^{93}$$Zr, a LLFP, was determined by ICP-MS after separating Zr from a spent nuclear fuel solution using a microvolume anion-exchange cartridge (TEDA cartridge). The TEDA cartridge achieved highly selective separation of Zr regardless of its small bed volume of 0.08 cm$$^{3}$$. The time taken to complete the Zr separation was 1.2 min with a flow rate of 1.5 mL/min, which was 10 times faster than that for a conventional anion-exchange resin column. Almost all the other elements were removed, leading to accurate measurement of $$^{93}$$Zr. The result connects experimental value to theoretical prediction provided by ORIGEN2, which requires verification. With the measured value, we demonstrated that the theoretical value is reliable enough to estimate radiation risks.

Oral presentation

Performance evaluation of micro-volume anion-exchange filter prepared by graft polymerization on Zr separation and its application to determination of Zr-93 in spent fuel

Asai, Shiho; Hanzawa, Yukiko; Konda, Miki; Suzuki, Daisuke; Magara, Masaaki; Kimura, Takaumi; Ishihara, Ryo*; Saito, Kyoichi*; Yamada, Shinsuke*; Hirota, Hideyuki*

no journal, , 

$$^{93}$$Zr is a long-lived fission product which can be found in spent nuclear fuel and HLW. The estimation of the$$^{93}$$Zr content is indispensable to achieve a safety disposal of HLW because $$^{93}$$Zr is predicted to be one of the major contributors to radiation dose. However, only a few measured $$^{93}$$Zr values have been reported, leading to a high demand for development of an efficient analytical method. Our group has been prepared a new porous filter cartridge which has densely bound ion-exchanger onto the pore surface of the filter, enabling a high-capacity and rapid adsorption. In order to apply this filter cartridge to a pretreatment for the $$^{93}$$Zr measurement with ICP-MS, an elution profiles of Zr and the other coexisting elements were examined. According to the resultant separation conditions, Zr in a spent nuclear fuel sample was successfully separated. The measured $$^{93}$$Zr content is 98.2 $$pm$$ 5.1 ng, which agrees with the theoretical value.

3 (Records 1-3 displayed on this page)
  • 1